Datasheet
Relays for functional safety
Safety relays PNOZsigma
PNOZ s30
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
849
Basic settings Ini pnp pnp
Settings for basic configuration 1
Level
Designation
on the display
Description Settings
1 Basic Parameter
Ini pnp pnp
Default
Load?
Select the default settings with
which the basic configuration
menu Ini pnp pnp is to be called:
-Load : The basic parameters are
loaded. Then it switches to the ba-
sic menu Ini pnp pnp.
The basic parameters should al-
ways be loaded when commis-
sioning for the first time.
- Edit: The basic parameters are
not loaded, i.e. all parameters are
retained. The basic menu para-
meters can be changed within the
permitted boundaries.
- Escape: Exits the basic menu.
2 Standstill
Rel.1 Out 1
Default
2.00 Hz
Enter standstill frequency 100 mHz ... 10.0 Hz
2 v max
Rel.2 Out 2
Default
500 Hz
Enter the max. permitted speed 10 mHz ... 3.00 kHz
Other, pre-defined settings:
} Encoder type
2 pnp type proximity switches
} Parameter set/select input
P0, select inputs are ignored (Select inputs mode: "None")
} Hysteresis
Standstill and speed, 2 % each
} Output assignment
– Standstill: Relay output Rel.1 and semiconductor output Out 1
– Speed: Relay output Rel.2 and semiconductor output Out 2