Datasheet
Relays for functional safety
Safety relays PNOZ X
PZE X4.1P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
434
Number of cycles x 1000
Switching current (A)
Fig.: Service life graphs at 110 VDC
Example
} Inductive load: 0.2 A
} Utilisation category: AC15
} Contact service life: 1 000 000 cycles
Provided the application to be implemented requires fewer than 1 000 000 cycles, the PFH
value (see Technical details [ 424]) can be used in the calculation.
To increase the service life, sufficient spark suppression must be provided on all relay con-
tacts. With capacitive loads, any power surges that occur must be noted. With DC contact-
ors, use flywheel diodes for spark suppression.
Order reference
Type Features Connection type Order no.
PZE X4.1P 24 VDC Screw terminals, plug-in 777 587
PZE X4.1P C 24 VDC Spring-loaded terminals, plug-in 787 587
PZE X4.1P 24-240 V AC/DC Screw terminals, plug-in 777 588
PZE X4.1P C 24-240 V AC/DC Spring-loaded terminals, plug-in 787 588










