Datasheet
Relays for functional safety
Safety relays PNOZ X
PNOZ XV2.1P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
340
Conventional thermal current
while loading several contacts
787542 787548
Ith per contact at UB DC;
AC1:240V,DC1:24V
Conv. therm. current with 1 con-
tact 8 A 8 A
Conv. therm. current with 2 con-
tacts 7 A 7 A
Conv. therm. current with 3 con-
tacts 5,7 A 5,7 A
Conv. therm. current with 4 con-
tacts 5 A 5 A
Times 787542 787548
Switch-on delay
With automatic start typ. 400 ms 400 ms
With automatic start max. 550 ms 550 ms
With automatic start after power
on typ. 820 ms 820 ms
With automatic start after power
on max. 1.100 ms 1.100 ms
With monitored start typ. 35 ms 35 ms
With monitored start max. 60 ms 60 ms
Delay-on de-energisation
With E-STOP typ. 15 ms 15 ms
With E-STOP max. 30 ms 30 ms
With power failure typ. UB 240 V 1 s 1 s
With power failure max. UB 240
V 1450 ms 1450 ms
With power failure typ. UB 24 V 130 ms 130 ms
With power failure max. UB 24 V 170 ms 170 ms
Recovery time at max. switching
frequency 1/s
After E-STOP 50 ms +tv 50 ms +tv
After power failure on wide-
range power supply 1500 ms 1500 ms
Delay time tv
0,1 s, 0,2 s, 0,3 s, 0,4 s, 0,5 s, 0,6
s, 0,7 s, 0,8 s, 1 s, 1,5 s, 2 s, 3 s
0,3 s, 5 s, 10 s, 20 s, 40 s, 60 s,
80 s, 100 s, 150 s, 200 s, 250 s,
300 s
Time accuracy -15 %/+15 % +50 ms -15 %/+15 % +50 ms
Repetition accuracy 2 % 2 %
Waiting period with a monitored
start 300 ms 300 ms
Min. start pulse duration with a
monitored start 30 ms 30 ms