Datasheet

Relays for functional safety
Safety relays PNOZsigma
PNOZ s50
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
927
Overview Display Description
Load configuration from chip card
Load Config from
Card
Download paramet-
ers from the chip
card to the device
Load Config
from Card
Are you sure?
No Yes
Are you sure? – Security prompt
No – Do not download parameters from
chip card
Yes – Download parameters from chip
card
Save configuration to chip card
Store Config to
Card
Download paramet-
ers from the device
to the chip card
Store Config
to Card
Are you Sure?
No Yes
Are you sure? - Security prompt
No – Do not save parameters to chip card
Yes – Save parameters to chip card
Restore default settings
Reset Config to
Default
Reset configuration
to default settings
Reset Config
to Default
Are you sure?
No Yes
Are you sure? – Security prompt
No – Do not load default settings
Yes – Load default settings
Configure supply voltage B1/B2 to the power circuits
Input
Switch to the menu
for the supply
voltage to the
power circuits
Input
B1/B2
B1/B2 – Switch to the Input Voltage
menu to configure the inputs B1/B2
Input Voltage
Configure the sup-
ply voltage to the
power circuits
Input Voltage
B1/B2
U 24 V
Cancel Store
U < 24 > V – Select supply voltage for
power circuit, values: 24 V, 48 V
Cancel – Exit menu without confirming the
entry
Store – Confirm entry
Configure feedback loops Y1 and Y2
Feedback
Configure feedback
loops
Feedback
Pulsing
Y1
Y2
Pulsing – Configure test pulses
Y1 – Switch to the Y1 menu to configure
feedback loop Y1
Y2 – Switch to the Y2 menu to configure
feedback loop Y2