Datasheet
Relays for functional safety
Safety relays PNOZsigma
PNOZ s50
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
913
Use chip card
The parameters that are set on a device are stored on the chip card. The data is stored
along with a device identifier and check sum. We recommend that you always operate the
unit with a chip card.
When the chip card is inside the unit,
} The chip card is checked to verify the device identifier, valid parameters, and ensure
that the data is identical.
} Device parameters are automatically saved to the chip card during configuration. As a
result, the chip card always contains a copy of the unit's current internal data.
When the device is switched on in the Power On operating state (all LEDs illuminate briefly)
a test is carried out to check whether
} a chip card is inserted or just an empty chip card holder.
} data on the chip card matches the data in the device.
} data on the chip card is valid.
In the Configuration operating state ("Run" LED flashes):
} The data is written to the chip card during configuration.
In the RUN operating state ("Run" LED is lit):
} The chip card containing a valid configuration must be inserted.
} The chip card must not be removed during operation.
Insert chip card
Make sure that you do not bend the chip card as you insert it into the chip card slot.
Save configuration with Software SmartCardCommander
You have the option to save a PNOZ s50 configuration from the chip card to your computer.
The configuration can be saved on the computer and then downloaded to other chip cards.
To do this you will need the chip card reader PNOZ Chip Card Reader with the corres-
ponding SmartCardCommander software. Both are available from Pilz as accessories, in-
dividually or as part of a set (see Order references Accessories [ 939]).