Datasheet
Relays for functional safety
Safety relays PNOZsigma
PNOZ s50
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
901
T
over
U
B1B2
U
Avg
S35, S36
Y10, Y11
Y20, Y21
01+, 02+
t
t
Y1, Y2
t
T
on
T
off
t
on
t
off
O4, O5
t
Fig.: Ventilation and application time
Legend:
} Y10, Y11, Y20, Y21: Safe inputs to switch the outputs O1+/O1-, O2+/O2-
} O1+, O2+: Safe outputs, power circuit 1 and 2
} U
B1B2
: Supply voltage to the power circuits
} t
on
: Switch on power circuit
} t
over
: Configured overexcitation time
} t
off
: Switch off power circuit
} U
Avg
: Configured reduced voltage (arithmetic mean of the voltage at the outputs once
the overexcitation time has elapsed)
} Y1, Y2: Feedback loops
} T
on
: Configured duration of max. ventilation time
} T
off
: Configured duration of max. application time
} O4, O5: Failsafe outputs for status of the load, change in state after T
on
and T
off
have
elapsed