Datasheet

Relays for functional safety
Safety relays PNOZsigma
PNOZ s30
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
870
Relay outputs 750330 751330
Utilisation category of auxiliary con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 4,0 A 4,0 A
Max. power 1000 VA 1000 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 4,0 A 4,0 A
Max. power 100 W 100 W
Utilisation category
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Utilisation category of safety con-
tacts
AC15 at 230 V 230 V
Max. current 3,0 A 3,0 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 4,0 A 4,0 A
Utilisation category of auxiliary con-
tacts
AC15 at 230 V 230 V
Max. current 3,0 A 3,0 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 4,0 A 4,0 A
External contact fuse protection,
safety contacts
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Blow-out fuse, quick 6 A 6 A
Blow-out fuse, slow 4 A 4 A
Circuit breaker 24V AC/DC,
characteristic B/C 4 A 4 A
External contact fuse protection,
auxiliary contacts
Blow-out fuse, quick 6 A 6 A
Blow-out fuse, slow 4 A 4 A
Circuit breaker 24 V AC/DC,
characteristic B/C 4 A 4 A
Conventional thermal current 4,0 A 4,0 A
Contact material AgCuNi + 0,2 µm Au AgCuNi + 0,2 µm Au