Level
Designation
on the display
Description Settings
1 Encoder Settings Create encoder configuration for
the tracks A,
/A, B, /B, Z, /Z, S
2 Encoder
Default
Undefined
Select pre-defined encoder types
for the tracks A, B and Z:
Proximity switch
Encoder
- with and without inverted signals
- with or without Z-Index (0-Index)
- with proximity switch at track Z
Reference:
If "Undefined" is selected, an error
message is shown when you con-
firm the menu
No encoder selected:
-
Undefined
Proximity switch (Ini):
- Initiator A: pnp B: pnp
- Initiator A: npn B: pnp
- Initiator A: pnp B: npn
- Initiator A: npn B: npn
Rotary encoder:
TTL
- TTL differential (A, /A, B, /B)
- TTL single ended (A, B)
TTL with Z-Index
-TTL diff. Z index (A, /A, B, /B, Z, /Z)
- TTL single Z index (A, B, Z)
HTL
- HTL differential (A, /A, B, /B)
- HTL single ended (A, B)
HTL with Z-Index
- HTL diff. Z index (A, /A, B, /B, Z, /Z)
- HTL single Z index (A, B, Z)
Sin/Cos 1 Vss
- sin/cos 1 Vss (A, /A, B, /B)
Sin/Cos 1 Vss with Z-Index
- sin/cos 1 Vss Z Index (A, /A, B, /B, Z, /
Z)
Hiperface
- Hiperface (A, /A, B, /B)