Datasheet
Relays for functional safety
Safety relays PNOZsigma
PNOZ s30
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
852
Settings
Level
Designation
on the display
Description Settings
1 Permanent Display
Default
H : Min : Sec (system
time)
v (current speed of
track AB)
Position
Permanent display
Current values and information re-
garding configuration are dis-
played.
You can change the permanent
display on the display
Display combinations:
-vz (current speed of track Z)
-v (current speed of track AB)
- Position
- Switch functions F1...F9
- v (current speed of track AB)
- Position
- Line 1/2: F1/F2, F3/F2, F5/F4, F7/F6
or F9/F8
(parameters selected via select inputs).
v (current speed of track AB)
- H : Min : Sec (system time)
- v (current speed of track AB)
- Position
1 Displ. Units
Speed: Dist:
Default
Hz Imp
Select unit of speed and distance
(position).
Speed: (speed) - Pos. (distance/posi-
tion)
Hz Imp (pulse)
Hz Edg (edge)
m/s m
m/min m
m/h m
rps rot
rpm rot
1 Conversion
Default
1 Hz= 1 Imp/s
Unit conversion.
Enter ratio of unit to pulses.
Display
1 Hz= 1 Imp/s
1 Hz = 4 Edg/s
1 m = x Imp (x = 1 ... 10,000,000
pulses)
1 rot = x Imp (x = 1 ... 10,000,000
pulses)