Datasheet
Relays for functional safety
Safety relays PNOZsigma
PNOZ s6.1
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
684
Unit types with UB 48 - 240 VAC/DC
} U
B
: 48 - 240 VAC/DC; Order no. 750156, 751156
Interface
expansion
module
Fig.: Centre: Front view with cover, right: Front view without cover
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)
Function description
} The safety relay must be activated by simultaneously pressing two control elements
(pushbuttons) within 0,5 s . If one or both pushbuttons are released or the contacts
open, the unit interrupts the control command for the hazardous movement.
} Reactivation: The output relays will not re-energise until both control elements have
been released and re-operated simultaneously or the contacts have opened and then
closed.