Selection guide
PNOZ X
Type Application
Performance
Level (PL) -
EN ISO 13849-1
Safety Integrity
Level (SIL)
CL – Claim limit in
accordance with
IEC62061
Output contacts
Housing width
in mmSafety-related Not safety-related
PNOZ X1P
e 3
3 - 1 -
22.5
PNOZ X2P
e 3
2 - - -
22.5
PNOZ X2.1VP
d 3
2 2 - 1
22.5
PNOZ X2.3P
e 3
3 - - -
22.5
PNOZ X2.7P
e 3
3 - 1 -
22.5
PNOZ X2.8P
e 3
3 - 1 -
22.5
PNOZ X2.9P
e 3
3 - 1 -
22.5
PNOZ X3P
e 3
3 - 1 1
45.0
PNOZ X3.10P
e 3
3 - 1 1
45.0
PNOZ X7P
e 3
2 - - -
22.5
PNOZ X8P
e 3
3 - 2 2
45.0
PNOZ X9P
e 3
7 - 2 2
90.0
PNOZ X10.11P
e 3
6 - 4 -
90.0
PNOZ X11P
e 3
7 - 1 2
90.0
PNOZ XV1P
e (d) * 3
2 1 - -
22.5
PNOZ XV2P
e (d) * 3
2 2 - -
45.0
PNOZ XV2.1P
e (d) * 3
2 2 - -
90.0
PNOZ XV3P
e (d) * 3
3 2 - -
45.0
PNOZ XV3.1P
e (d) * 3
3 2 1 -
90.0
PZE X4P Contact expansion e 3
4 - - -
22.5
PZE X4.1P Contact expansion e 3
4 - - -
22.5
PZE X4VP Contact expansion d 2
4 - - -
22.5
PZE X4VP4 Contact expansion d 2
4 - - -
45.0
PZE X4VP8 Contact expansion d 2
4 - - -
45.0
Relays for functional safety