Datasheet

Relays for functional safety
Safety relays PNOZ X
PMUT X1P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
502
Function description
The muting controller PMUT X1P is used for the temporary suspension of safety functions.
This allows objects to be transported into and out of a danger zone without adversely af-
fecting the safety function. When the supply voltage is applied the "POWER" LED will light.
The unit is ready for operation when the feedback loop Y1-Y2 and the input circuit (e.g. light
guard at S12 and S22 not interrupted) are closed. The muting sensors are not active.
} Start circuit S33-S34 is closed:
Safety contacts 13-14/23-24/33-34 are closed, auxiliary contact 41-42 is open.
Status indicators "Output", "OSSD CH.1" and "OSSD CH.2" are lit.
A high signal is present at the semiconductor output Y32 (ESPE state).
A high signal is present at the semiconductor output Y36 (switch state of safety con-
tacts)
} Input circuit is opened (e.g. light guard at S12 and S22 interrupted):
Safety contacts 13-14/23-24/33-34 are opened redundantly, auxiliary contact 41-42
is closed.
Status indicators "Output", "OSSD CH.1" and "OSSD CH.2" go out.
A low signal is present at the semiconductor output Y36 (switch state of safety con-
tacts).
A low signal is present at semiconductor output Y32 (ESPE state).