Datasheet
Relays for functional safety
Safety relays PNOZ X
PNOZ X2P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
25
Type: 48-240 V AC/DC
} U
B
: 48-240 VAC/DC; Order no. 777307, 787307
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)
Function Description
The safety relay PNOZ X2P provides a safety-oriented interruption of a safety circuit. When
supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the
start circuit S33-S34 is closed.
} Input circuit is closed (e.g. E-STOP pushbutton not operated):
– Safety contacts 13-14 and 23-24 are closed, the unit is active.
– The LEDs "CH.1" and "CH.2" are lit.
} Input circuit is opened (e.g. E-STOP pushbutton operated):
– Safety contacts 13-14 and 23-24 are redundantly opened.
– The LEDs "CH.1" and "CH.2" go out.
Operating modes
} Single-channel operation (only 24 VAC/DC units): No redundancy in the input circuit,
earth faults in the start and input circuit are detected.
} Dual-channel operation with detection of shorts across contacts: Redundant input cir-
cuit, PNOZ X2P detects
– earth faults in the start and input circuit,
– short circuits in the input circuit,
– shorts across contacts in the input circuit.