Datasheet
Relays for functional safety
Safety relays PNOZ X
PNOZ X8P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
212
Example
} Inductive load: 0.2 A
} Utilisation category: AC15
} Contact service life: 4 000 000 cycles
Provided the application to be implemented requires fewer than 4 000 000 cycles, the PFH
value (see Technical details) can be used in the calculation.
To increase the service life, sufficient spark suppression must be provided on all output
contacts. With capacitive loads, any power surges that occur must be noted. With DC con-
tactors, use flywheel diodes for spark suppression.
Order reference
Product type Features Connection type Order no.
PNOZ X8P 24 VAC Screw terminals 777 770
PNOZ X8P C 24 VAC Spring-loaded terminals 787 770
PNOZ X8P 110 V AC Screw terminals 777 764
PNOZ X8P C 110 V AC Spring-loaded terminals 787 764
PNOZ X8P 115 V AC Screw terminals 777 765
PNOZ X8P 120 V AC Screw terminals 777 766
PNOZ X8P C 120 V AC Spring-loaded terminals 787 766
PNOZ X8P 230 V AC Screw terminals 777 768
PNOZ X8P C 230 V AC Spring-loaded terminals 787 768
PNOZ X8P 24 VDC Screw terminals 777 760
PNOZ X8P C 24 VDC Spring-loaded terminals 787 760