Datasheet

Relays for functional safety
Safety relays PNOZ X
PNOZ X3.10P
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com
2016-09
148
Block diagram/terminal configuration
*
0 V 24 V
Y30 Y31
S11 S12 S21 S22 S31 S32
Y32 S13 S14 S15 S16 S33 S34
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)
Function Description
The safety relay PNOZ X3.10P provides a safety-oriented interruption of a safety circuit.
When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation
when the start circuit S13-S14 is closed.
} Input circuit is closed (e.g. E-STOP pushbutton not operated):
Safety contacts 13-14, 23-24 and 33-34 are closed, auxiliary contact 41-42 is open.
The unit is active.
The LEDs "CH.1" and "CH.2" are lit.
A high signal is present at the semiconductor output switch state Y32.
} Input circuit is opened (e.g. E-STOP pushbutton operated):
Safety contacts 13-14, 23-24 and 33-34 are opened redundantly, auxiliary contact
41-42 is closed.
The LEDs "CH.1" and "CH.2" go out.
A low signal is present at the semiconductor output switch state Y32.
Operating modes
} Single-channel operation: No redundancy in the input circuit, earth faults in the start
and input circuit are detected.
} Dual-channel operation with detection of shorts across contacts: Redundant input cir-
cuit, PNOZ X3.10P detects
earth faults in the start and input circuit,
short circuits in the input circuit,