Removethesensorandtightenscrew(c).
Alignthesensortotheactuatorandtightenthescrews.
Adjustment
} Thestatedoperatingdistances(seeTechnicaldetails:Systemwithnormal
actuator[ 25],Systemwithfreemovingactuator[ 28],undermechanicaldata)
onlyapplywhenthesafetyswitchandactuatorareinstalledfacingeachotherinparal
lel.Operatingdistancesmaydeviateifotherarrangementsareused.
} Notethemaximumpermittedlateralandverticaloffset(seeLateralandvertical
offset[ 10]).
Operation
Checkthefunctionofthesafetyswitchbeforecommissioning.
Anydeviationsfromthepropertiesandfunctionsdescribedintheseoperatingin
structionscanleadtohazardoussituations.
CAUTION!
Contaminatedsurfacescanreducetheholdingforceoftheelectromagnet.
Makesurethatthecontactsurfacesareclean.
Statusindicators:
} "Power/Fault"LEDilluminatesgreen:Theunitisreadyforoperation
} "SafetyGate"LEDlightsupyellow:Actuatoriswithintheresponserange
} "Lock"LEDlightsupgreen:Magneticguardlockingdeviceactive
} "Input"LEDlightsupyellow:Thereisahighsignalattheinputs.