Datasheet
BAPSENsl1.0p1.1/1.1VA/2.1/2.2
OperatingManualBAPSENsl1.0p1.1/1.1VA/2.1/2.2
21909EN09
14
CAUTION!
Whenseveralunitsareconnectedinseries,themax.solenoidcurrentin
creasesindirectproportiontothenumberofinterconnectedsafetyswitches
(seeTechnicaldetails[ 25],Max.inrushcurrentimpulseA1).
ConnectiontoPilzevaluationdevices
ThesafetyswitchPSENsl1.0p1.1/1.1VA/2.1/2.2canbeconnectedtoPilzevaluation
devices,forexample.Makesurethatanevaluationdeviceisselectedthatcanevaluate
OSSDsignalsthroughtwochannels.
SuitablePilzevaluationdevicesare,forexample:
} PNOZelogforsafetygatemonitoring
} PNOZpowerforsafetygatemonitoring
} PNOZsigmaforsafetygatemonitoring
} PNOZXforsafetygatemonitoring
} PNOZmultiforsafetygatemonitoring
ConfiguretheswitchinthePNOZmultiConfiguratorwithswitchtype3.
} PSSforsafetygatemonitoringwithstandardfunctionblockSB064,SB066or
FS_SafetyGate
Thecorrectconnectiontotherespectiveevaluationdeviceisdescribedintheinstructions
fortheevaluationdevice.Makesurethattheconnectionismadeinaccordancewiththe
specificationsintheinstructionsfortheselectedevaluationdevice.
Theconnectionstotwoevaluationdevicesareshownonthefollowingpages,bywayofex
ample:
} PNOZs3and
} PNOZmulti
ConnectionexamplePNOZs3
PNOZ s3
PSENslock
0 V
24 V
A1
A2
S22
S12
A1
A2
Y32
S31
S11
S21
12
22
2
7
8
6
1
3
4
5