Connectiondiagram,seriesconnection
Actuator
Receiver
Evaluation device
24 V 0 V
A1
A2
12
22
I1 (FS) I2 (FS)
A1
A2
S31
O1 (ST)
FS: Failsafe
ST: Standard
Actuator
Actuator
Receiver
Receiver
PLC
A1
A2
O2 (ST)
O3 (ST)
S31
S31
12
22
12
22
A1
A2
S11
S21
S11
S21
S11
S21
Y32
Y32
Y32
I1 (ST)
I2 (ST)
I3 (ST)
CAUTION!
Extensionofdelayondeenergisation
Whenseveral(n)devicesareconnectedinseries,thedelayondeener
gisationtimeaddswiththenumberofinterconnectedsafetyswitches.
Themay.delayondeenergisationiscomposedof
max.delayondeenergisationactuator
+(n1)xmax.delayondeenergisationoftheinputs
+delayondeenergisationoftheevaluationdevice