Datasheet
BAPSENsl1.0p1.1/1.1VA/2.1/2.2
OperatingManualBAPSENsl1.0p1.1/1.1VA/2.1/2.2
21909EN09
10
Aswitchtoahighsignalwillonlyleadtonormalswitchoperationifbothinputshadalow
signal.Fromthismomenton,theswitchtohighmayoccur(partialoperationlockseeError
display[ 22]).
Magneticguardlockingdeviceandmagnetmonitoring
} ThelockingmagnetisswitchedonifS31(controlcommandformagneticguardlocking)
ishighandtheactuatorisdetected(safetygateclosed).
} Theholdingforceofthelockingmagnetistestedonpowerup.
} AfterS31switchestolow,waitatleast500msuntilS31isswitchedbacktohigh.Also
notethemax.switchingfrequency(seeTechnicaldetails[ 25]).
Ifanopenwindingorawindingshortcircuitisdetectedonalockingmagnetthatis
switchedon,safetyoutputs12and22switchtoalowstate.
} Forphysicalreasons,aremanence(residualmagnetism)remainsafterthelocking
magnetisswitchedoff;thisisdissipatedthefirsttimethesensorandactuatoraresep
arated.
} Ifthesafetygateisinalockedconditionandisopenedbyforce,thesafetyoutputswill
shutdown.
Lateralandverticaloffset
Verticaloffsetmax.5mm Lateraloffsetmax.3mm
Wiring
Pleasenote:
} Youmustcomplywiththespecificationsstatedinthetechnicaldetails(seeTechnical
details:Systemwithnormalactuator[ 25],Systemwithfreemoving
actuator[ 28],underelectricaldata,inputsandsemiconductoroutputs).
} Thepowersupplymustmeettheregulationsforextralowvoltageswithprotectivesep
aration(SELV,PELV).
} Theinputsandoutputsofthesafetyswitchmusthaveaprotectiveseparationto
voltagesover60VDC.
INFORMATION
Onlyusesafetyrelayswitha24VDCsupplyvoltage.Safetyrelayswithuni
versalpowersupplyorinACdeviceversionshaveinternalpotentialisola
tionandarenotsuitableasevaluationdevices.