Datasheet

36(1bPOE
52
PSENml b 1.1
Type code for PSENmlock
Product area
Pilz SENsors
Version Coding
Product range
ml – PSENmlock
b Base version 1.1
2.1
2.2
Coded
Fully coded
Unique, fully coded
Operation
ō Mechanical, coded
ō Transponder (RFID)
ō With safe semiconductor
outputs
3URGXFWJURXS6DIHW\JDWHV\VWHP36(1PORFN
Safety gate system PSENmlock
The safety gate system PSENmlock provides secure interlocking and secure guards for person and
process protection up to the highest safety category PLe.
Safe interlocking with safe guard locking
PSENmlock – safe interlocking and guard locking in one
product. The latter is enabled by the two-channel control
of the guard locking. The switch is therefore especially
suitable for machines with dangerous run-on, in which a
safe guard locking is also necessary up to PLd or PLe.
Because of LEDs on three sides of the housing, the
diagnostics is visible in all three installation positions.
The flexibly mounted actuator ensures a high tolerance
compensation – even with sagging doors. The mechanical
robustness and the robust housing make possible a long
service life and protection for your investment. Combined
with Pilz control technology, you receive a safe,
complete solution for guard monitoring.
Safety gate systems