DRAFT PicoScope 5000D Series ® FlexRes oscilloscopes and MSOs ® The complete all-rounders FlexRes® flexible 8 to 16-bit hardware resolution Up to 200 MHz analog bandwidth 1 GS/s sampling at 8-bit resolution 500 MS/s sampling at 12-bit resolution 62.5 MS/s sampling at 16-bit resolution Up to 512 MS capture memory 16 digital channels (on MSO models) 130 000 waveforms per second Built-in arbitrary waveform generator Serial decoding as standard (18 protocols) Up to 200 MHz spectrum analyzer DRAFT www.
Introduction DRAFT PicoScopes include advanced features such as mask limit testing, serial decoding, advanced triggering, automatic measurements, math channels (including the ability to plot frequency and duty cycle against time), XY mode and segmented memory. The PicoScope 5000D Series also benefits from Pico’s award-winning DeepMeasure™ feature and FlexRes® flexible resolution.
Advanced display Low-level signals DRAFT PicoScope software dedicates the majority of the display area to the waveform, ensuring that the maximum amount of data is visible at all times. The size of the display is only limited by the size of your computer’s monitor, so even with a laptop, the viewing area is much bigger, with much higher resolution, than that of a benchtop scope.
High bandwidth, high sampling rate DeepMeasure DRAFT Most USB-powered oscilloscopes have real-time sampling rates of only 100 or 200 MS/s, but the PicoScope 5000D Series offers up to 1 GS/s, and a maximum bandwidth of 200 MHz. Equivalent time sampling (ETS) mode can be used to further boost the sampling rate to 10 GS/s for a more detailed view of repetitive signals.
Mixed-signal models Persistence mode DRAFT The PicoScope 5000D MSO models add 16 digital channels to the 2 or 4 analog channels, enabling you to accurately time-correlate analog and digital channels. Digital channels may be grouped and displayed as a bus, with each bus value displayed in hex, binary or decimal or as a level (for DAC testing). You can set advanced triggers across both the analog and digital channels. The digital inputs also bring extra power to the serial decoding options.
Serial decoding and analysis DRAFT With its deep memory, the PicoScope 5000D Series is ideally suited to serial decoding and analysis, which are included as standard. The PicoScope 6 software has support for 18 protocols including I C, SPI, CAN, RS-232 and Ethernet. 2 Decoding helps you see what is happening in your design to identify programming and timing errors and check for other signal integrity issues.
Spectrum analyzer DRAFT The spectrum view plots amplitude against frequency and is ideal for finding noise, crosstalk or distortion in signals. PicoScope uses a fast Fourier transform (FFT) spectrum analyzer, which (unlike a traditional swept spectrum analyzer) can display the spectrum of a single, non-repeating waveform. With a click of a button, you can display a spectrum plot of the active channels, with a maximum frequency of up to 200 MHz.
Digital triggering architecture Advanced triggers DRAFT In 1991, Pico Technology pioneered the use of digital triggering and precision hysteresis using the actual digitized data. Traditionally, digital oscilloscopes have used an analog trigger architecture based on comparators, which can cause time and amplitude errors that cannot always be calibrated out. Additionally, the use of comparators can often limit the trigger sensitivity at high bandwidths and can create a long trigger rearm delay.
Mask limit testing Math channels and filters DRAFT Mask limit testing allows you to compare live signals against known good signals, and is designed for production and debugging environments. Simply capture a known good signal, generate a mask around it and then use the alarms to automatically save any waveform (complete with a time stamp) that violates the mask.
FlexRes® – how we do it High signal integrity DRAFT Most digital oscilloscopes gain their high sampling rates by interleaving multiple 8-bit ADCs. Despite careful design, the interleaving process introduces errors that always make the dynamic performance worse than the performance of the individual ADC cores.
SuperSpeed USB 3.0 connection DRAFT PicoScope 5000D Series oscilloscopes feature a USB 3.0 connection, providing lightning-fast saving of waveforms while retaining compatibility with older USB standards. The PicoSDK® software development kit supports continuous streaming to the host computer at rates up to 125 MS/s.
Connections The front panel of the 2-channel PicoScope 5000D Series oscilloscopes has: DRAFT The front panel of the 4-channel PicoScope 5000D Series oscilloscopes has: 2 x BNC analog input channels 4 x BNC analog input channels 1 x probe compensation pin 1 x probe compensation pin 1 x BNC external trigger input 1 x BNC external trigger input 1 x BNC AWG/function generator output 1 x BNC AWG/function generator output The rear panel has: The rear panel has: 1 x ground terminal 1 x ground termina
PicoScope 6 software The display can be as simple or as complex as you need. Begin with a single view of one channel, and then expand the display to include any number of live channels, math channels and reference waveforms. Tools: Including serial decoding, reference channels, macro recorder, alarms and mask limit testing. Auto setup button: Configures the collection time and voltage range for clear display of signals.
PicoScope 5000D Series Technical Specifications PicoScope 5242D and 5242D MSO 2-channel, 60 MHz DRAFT PicoScope 5243D and 5243D MSO 2-channel, 100 MHz PicoScope 5244D and 5244D MSO PicoScope 5442D and 5442D MSO PicoScope 5443D and 5443D MSO PicoScope 5444D and 5444D MSO 2 4 4 4 200 MHz 60 MHz 100 MHz 200 MHz 1.75 ns 5.8 ns 3.5 ns 1.
PicoScope 5000D Series Technical Specifications PicoScope 5242D and 5242D MSO 2-channel, 60 MHz DRAFT PicoScope 5243D and 5243D MSO 2-channel, 100 MHz PicoScope 5244D and 5244D MSO 2-channel, 200 MHz PicoScope 5442D and 5442D MSO 4-channel, 60 MHz PicoScope 5443D and 5443D MSO 4-channel, 100 MHz PicoScope 5444D and 5444D MSO 4-channel, 200 MHz Vertical (digital channels) – D MSO models only Input channels Input connector Maximum input frequency Minimum detectable pulse width Input impedance Input dy
PicoScope 5000D Series Technical Specifications PicoScope 5242D and 5242D MSO 2-channel, 60 MHz DRAFT PicoScope 5243D and 5243D MSO 2-channel, 100 MHz PicoScope 5244D and 5244D MSO 2-channel, 200 MHz 60 MHz models: 2 ns/div to 5000 s/div in 38 ranges Timebase ranges (ETS) 100 MHz models: 1 ns/div to 5000 s/div in 39 ranges 200 MHz models: 500 ps/div to 5000 s/div in 40 ranges Buffer memory** (8-bit) 512 MS Buffer memory** (≥ 12-bit) 256 MS Buffer memory*** 100 MS in PicoScope software (continuous strea
PicoScope 5000D Series Technical Specifications Trigger modes Advanced trigger types (analog channels) Trigger types (analog channels, ETS) Trigger sensitivity (analog channels) Trigger sensitivity (analog channels, ETS) Trigger types (digital inputs) Maximum pre-trigger capture Maximum post-trigger delay PicoScope 5242D and 5242D MSO 2-channel, 60 MHz DRAFT PicoScope 5243D and 5243D MSO 2-channel, 100 MHz PicoScope 5244D and 5244D MSO 2-channel, 200 MHz PicoScope 5442D and 5442D MSO 4-channel, 60 MHz
PicoScope 5000D Series Technical Specifications Output frequency range Standard signal frequency Sweep modes Triggering Output frequency accuracy Output frequency resolution Output voltage range Output voltage adjustments Amplitude flatness DC accuracy SFDR Output resistance Connector type Overvoltage protection PicoScope 5242D and 5242D MSO 2-channel, 60 MHz DRAFT PicoScope 5243D and 5243D MSO 2-channel, 100 MHz PicoScope 5244D and 5244D MSO 2-channel, 200 MHz PicoScope 5442D and 5442D MSO 4-channel,
PicoScope 5000D Series Technical Specifications DRAFT PicoScope 5242D and 5242D MSO PicoScope 5243D and 5243D MSO PicoScope 5244D and 5244D MSO PicoScope 5442D and 5442D MSO PicoScope 5443D and 5443D MSO PicoScope 5444D and 5444D MSO DC to 60 MHz DC to 100 MHz DC to 200 MHz DC to 60 MHz DC to 100 MHz DC to 200 MHz 2-channel, 60 MHz 2-channel, 100 MHz 2-channel, 200 MHz 4-channel, 60 MHz 4-channel, 100 MHz 4-channel, 200 MHz Spectrum analyzer Frequency range Display modes Magnitude, aver
PicoScope 5000D Series Technical Specifications Temperature range Humidity range Environment Safety approvals EMC approvals Environmental approvals Software PC requirements Accessories included Software languages PicoScope 5242D and 5242D MSO 2-channel, 60 MHz DRAFT PicoScope 5243D and 5243D MSO 2-channel, 100 MHz PicoScope 5244D and 5244D MSO 2-channel, 200 MHz PicoScope 5442D and 5442D MSO 4-channel, 60 MHz PicoScope 5443D and 5443D MSO 4-channel, 100 MHz PicoScope 5444D and 5444D MSO 4-channel,
Ordering information Order code PQ143 PQ149 PQ144 PQ150 PQ145 PQ151 PQ146 PQ152 PQ147 PQ153 PQ148 PQ154 DRAFT Model number Description USD* PicoScope 5242D PicoScope 5242D MSO PicoScope 5243D PicoScope 5243D MSO PicoScope 5244D PicoScope 5244D MSO PicoScope 5442D PicoScope 5442D MSO PicoScope 5443D PicoScope 5443D MSO PicoScope 5444D PicoScope 5444D MSO 60 MHz 2-channel oscilloscope 60 MHz 2-channel mixed-signal oscilloscope 100 MHz 2-channel oscilloscope 100 MHz 2-channel mixed-signal oscilloscope 20