Specifications

Owners Manual
13
CONTACT US 858.546.5050
www.picomacom.com
PICO MACOM
PICO-PRO/Q
Scan Measurement
Select the “SCAN” icon and press the Enter Key to enter the scan
measurement mode. (Fig. 18)
The Function Key Icons’ Definition:
: Zoom In
: Zoom Out
: Save
: Zoom In (Change Scale)
: Zoom Out (Change Scale)
: Pagedown
: PageUp
: Return
1. Level Reference Adjusting
The level reference displays at the bottom of the right side. It can be adjusted by pressing Up and Down Key.
The step of level reference is 5dB.
2. Zoom In and Out
Press F1 (
) and F2 (
).
3. Save
Press F3 (
).
4. Scale Adjusting
Press F4 to switch the Function Key to the next page. Then press F1 (
) and F2 (
) to change the scale among 20, 10,
5, 2, 1 db/div.
5. Mark Moving
Press Left and Right Key to move the mark. At the bottom of the LCD, there’s the channel number and frequency.
6. Starting Channel Input
Press the Numbers Keys and the CH Key. The device will start the scan measurement with the new starting channel.
Tilt Measurement
Select the “TILT” icon and press the Enter Key to enter the tilt
measurement mode. (Fig. 19)
There’re 12 vertical bands each represents one channel signal level. You can
compare the channels’ amplitude-frequency response through the multi-channel
measurement which is also called tilt measurement.
You can change the channel on the mark by pressing Up/Down Key and Enter
Key to save. And also you can move the mark by Left/Right Key. At the bottom
of the LCD, there’re the maximum channel’s number and frequency, the
minimum one and also
dB value displaying on the right.
Attention: Please make sure the channels which will be measured array
continuously.
Fig. 18
Fig. 19