Certifications 2
Data Sheet
Document No: PW-QW-TD-GGS-00107
Version: A-0
Page: 4/7
8.Exposure Controls/Personal Protection
Respiratory protection: No necessary under normal use. In case electrolyte leakage from
battery, protect hand with chemical resistant rubber gloves. If battery is burning, leave the area
immediately. In abuse, use NIOSH approved acid gas filter mask or self-contained breathing
apparatus.
Ventilation: No necessary under normal use. In case of abuse, use adequate mechanical
ventilation for battery that vent gas or fumes.
Protective gloves: None under normal use. In case of spill use PVC, neoprene or nitrile gloves of
15 mils(0.015 inch) or thicker.
Eye protection: None required under normal conditions. Use ANSI approved chemical work
safety goggles or face shield, if handling a leaking or rupture battery.
Skin protection: No necessary under normal use. Use rubber apron and protective working in
case of handling of a rupture battery.
Other protective equipment: Chemical resistance clothing is recommended along with eye
wash station and safety shower should be available meeting ANSI design criteria.
Work hygienic practice: Use good chemical hygiene practice. Wash hands after use and before
drinking, eating or smoking. Wash hands thoroughly after cleaning-up a battery spill caused by
leaking battery. No eating, drinking, or smoking in battery storage area. Launder contaminated
cloth before reuse.
Supplementary safety and health data: If the battery is broken or leaked the main hazard is the
electrolyte. The electrolyte is mainly solution of LiPF6,EC,EMC and DEC.
9.Physical and Chemical Properties
Physical state: Solid-article
Freezing point: N/A
Boiling point: N/A
Density: N/A
Vapor pressure: N/A
Vapour density: N/A
Flash point: N/A
Evaporation rate: N/A
10.Stability and reactivity
Stability: Stable during normal operation conditions.
Conditions/materials to avoid: Incompatible with water, moisture, strong oxidizing agents,
reducing agents, acids and bases.