Operation Manual

a This instruction booklet contains all the necessary information for installation, operation and maintenance.
Only call the Gruppo Piazzetta S.p.A. service centre after having scrupulously followed all the instructions.
Appliance runs for 9-10 minutes and
then goes out
Heat sensor locked
Repeat ignition procedure. If the
problem persists, contact an
authorised technician
Combustion gases have not reached
the required ignition temperature
Repeat ignition procedure. If the
problem persists, contact an
authorised technician
Heat sensor badly connected Check the wiring and connections
Blocked ue Clean ue system
Failed ignition See “NO ACC”
Faulty electronic board
Replace the electronic board (use only
original spares)
Pellet-charging system blocked
Empty the pellet hopper; check and
clean the auger and chute