Operation Manual
Stove safety device
“MASS TEMP” stove status
Blocked ue or ue gas outlet Clean the ue and the outlet
Faulty electronic board
Replace the electronic board (use only
original spares)
Faulty limit temperature control sensor
Replace the control sensor (use only
original spares)
Badly positioned smoke sensor
Check that the sensor is correctly
positioned (see wiring diagram)
Incorrect parameter settings Check parameter settings
Smoke sensor
“NO CONN” stove status
No connection between the 2-pin
terminal of the smoke sensor or the
ambient and the electronic board
Check correct insertion/position of the
connector (see wiring diagram)
Faulty electronic board
Replace the electronic board (use only
original spares)
Badly positioned smoke sensor
Check that the sensor is correctly
connected
Problem Cause Solution
“PUL” stove status
Momentary power failure during
operation
The stove restarts automatically and
continues operating normally at power
level 2
“NO ACC” stove status Empty hopper Fill the hopper
Grate requires cleaning Clean the grate (see section 7.1)
Faulty glow plug (igniter)
Replace glow plug (use only original
spares)
Faulty electronic board
Replace the electronic board (use only
original spares)
Operating temperature not reached
Empty the grate and restart
H07032120 / DT2002308 – 00
67
English