Operation Manual

FLUE GAS TEMPERATURE SENSOR
Sensor Description Display
Smoke sensor
Connected to the electronic board, it constantly monitors the working
temperature allowing the stove to be used in all safety.
WHEN ACTIVATED
If the temperature exceeds the xed safety limit the board cuts off the
power supply to the fuelloading auger thus depriving the grate of pellets
and starting the stove shutdown process.
In the upper part of the display appears the message “SAFETY and in
the lover part appears STOVE”.
The readout ”MASS TEMP” and the ue gas temperature appear in the
STOVE STATUS mode.
After approx. 60 seconds the alarm sounds (if activated).
!
!
1
1
SAFETY
STOVE
PROBE
SMOKE
12:00 73F
12:00 73F
WHAT TO DO
Shut down the stove by holding the ON/OFF key down for several seconds.
• The alarm stops.
Wait until you are sure that combustion of any pellets remaining in the grate
has stopped.
• Check for and remove whatever has triggered the safety device.
After having cleaned the grate restart the stove by pressing the ON/OFF key.
Smoke sensor
Disconnected
WHEN ACTIVATED
If the sensor is momentarily or accidentally removed from its normal
position, or is not connected properly to the electronic board, the readout
NO CONN and the ue gas temperature will appear in the STOVE STATUS
mode.
After approx. 60 seconds the alarm sounds (if activated).
!
!
1
1
SAFETY
STOVE
PROBE
SMOKE
12:00 73F
12:00 73F
WHAT TO DO
Shut down the stove by holding the ON/OFF key down for several
seconds.
The alarm stops.
Call the After-Sales Service Centre.
DT2040054-05
STOVE ROOM TEMPERATURE SENSOR
Sensor Description Display
Room sensor
Connected to the rear of the stove, it constantly monitors the temperature
in the immediate vicinity of the stove to ensure that it can be operated in
all safety.
WHEN ACTIVATED
If the sensor is momentarily or accidentally removed from its normal
position, the problem does not require the immediate shutdown of the
stove, which will continue to operate normally at the set power level.
The problem will be indicated on the display by the readout “ton”.
LEVEL
P2
12:00TON
1
WHAT TO DO
Put the sensor back in its proper position.
If the room temperature display has been activated, it will once again
be shown.
DT2040055-03
H07032120 / DT2002308 – 00
58
English