Operation Manual

PELLET HOPPER HOUSING TEMPERATURE
Sensor Description Display
Thermostat with
automatic reset
Located on the pellet hopper, its function is to prevent excessive
temperature ranges.
WHEN ACTIVATED
If the pellet hopper temperature reaches critical levels, the thermostat
cuts off the power supply to the fuel-loading auger, thereby stopping the
supply of pellets to the grate and starting the stove shutdown process.
The readout ‘ALC’ appears in the STOVE STATUS mode.
After approx. 60 seconds the alarm sounds (if activated).
!
1
TANK TEMP
SAFETY
12:00 73F
WHAT TO DO
Shut down the stove by holding the ON/OFF key down for several seconds.
The alarm will stop.
Wait until combustion of any pellets remaining in the grate has nished.
After having cleaned the grate, restart the stove by pressing the ON/
OFF key. (The readout TANK TEMP SAFETY must no longer appear on
the display. If this is not the case repeat the process described above.)
DT2010995-00
FLUE GAS FAN RUNNING
Sensor Description Display
Its function is to check correct operation of the ue gas fan so that the
stove can be used in all safety.
If the black-red-white cable connected to the ue gas fan (see the
paragraph “WIRING DIAGRAM”) momentarily or accidentally removed
from its normal position, or is not connected properly to the electronic
board, or the speed of the smoke fan is greater or lower than the set value
according to settings smoke parameter, the readout “ALF 3 or “ALF 4
will appear in STOVE STATUS MODE.
- The readout “SMOKE FAN FAILURE appears on the display.
- After approx. 60 seconds the alarm sounds (if activated).
!
1
SMOKE FAN
FAILURE
12:00 73F
WHAT TO DO
- Shut down the stove by holding the ON/OFF key down for several
seconds.
- The alarm stops.
- Call the After-Sales Service Centre.
DT2012666-00
H07032120 / DT2002308 – 00
57