Operation Manual

Description of activity Display
The door open sensor veries that the door to the appliance has been correctly closed.
WHEN ACTIVATED:
If the door remains open, the switch cuts off the power supply to the fuel-loading
auger, thereby stopping the supply of pellets to the grate. If the door remains open for
more than 60 consecutive seconds, the stove starts the shut-down procedure after a
30-second audible beep activates to request that the door be fully closed simultaneously
with the readout “CLOSE SLIDING TOP-DOOR” appearing on the display.
- The readout “ALF 1” appears in the STOVE STATUS mode.
- The readout “SMOKE SAFETY” appears on the display;
- The alarm sounds (if activated).
CLOSE
SLIDING
1
!
!
1
1
SMOKE
SAFETY
SMOKE
SAFETY
12:00 73F
12:00 73F
WHAT TO DO:
- Shut down the stove by holding the ON/OFF key down for several seconds.
- The alarm stops.
- Wait until you are sure that combustion of any pellets remaining in the grate has
stopped.
- Wait until the stove has cooled down, then check for and remove whatever has
caused the safety device to be triggered. Finally, after having cleaned the grate
restart the stove by pressing the ON/OFF key.
Description of activity Display
Connected to the fuel hopper lid, its function is to disable the fuel feed auger motor
when the hopper lid is open as required by UL and ULC standards.
WHEN ACTIVATED:
If the sliding top panel remains open, the lid switch cuts off the power supply to the
fuel-loading auger, thereby stopping the supply of pellets to the grate. If the sliding
top panel remains open for more than 60 consecutive seconds, the stove starts the
shutdown procedure after a 30-second audible beep activates to request that the
sliding top panel be fully closed. The hopper lid must be closed before sliding the panel
into its fully closed position and the readout “CLOSE SLIDING TOP-DOOR” appears on
the display.
a If the sliding top panel is not left in its fully closed position a 30-second
audible beep activates to request that the sliding top panel is manually
returned to its fully closed position, otherwise the stove will go into the
shut-down procedure.
- The readout “ALF 1” appears in the STOVE STATUS mode.
- The readout “SMOKE SAFETY” appears on the display.
- The alarm sounds (if activated).
CLOSE
SLIDING
1
!
!
1
1
SMOKE
SAFETY
SMOKE
SAFETY
12:00 73F
12:00 73F
WHAT TO DO:
- Shut down the stove by holding the ON/OFF key down for several seconds.
- The alarm stops.
- Wait until you are sure that combustion of any pellets remaining in the grate has
stopped.
- Wait until the stove has cooled down, then check for and remove whatever has
caused the safety device to be triggered. Finally, after having cleaned the grate
restart the stove by pressing the ON/OFF key.
FIRE DOOR SENSOR
FUEL HOPPER LID SENSOR
H07032120 / DT2002308 – 00
56
English