Operation Manual
DT2010242-05
6.11 TIMER
Function Action Display
Select set chrono
menu
Press the MENU key. Using the SELECT MENU key select the SET CHRONO
menu and conrm by pressing the SET key.
1
1
1
1
1
1
1
1
1
1
SET
CHRONO
PROGRAM
DAY
ENABLE
DAY
OFF
START D
PROGRAM 1
06 :00
STOP D
PROGRAM 1
0 9:00
STOP D
PROGRAM 1
OFF
SET D
POWER 1
01
77F
SET D
VENT-1
01
START D
PROGRAM 2
20 :30
SET ROOM
TEM P. 1
Select day
programme
Using the SELECT MENU key select the day-programme “PROGRAM DAY”
menu and conrm by pressing the SET key.
1
1
1
1
1
1
1
1
1
1
SET
CHRONO
PROGRAM
DAY
ENABLE
DAY
OFF
START D
PROGRAM 1
06 :00
STOP D
PROGRAM 1
0 9:00
STOP D
PROGRAM 1
OFF
SET D
POWER 1
01
77F
SET D
VENT-1
01
START D
PROGRAM 2
20 :30
SET ROOM
TEM P. 1
Enable or disable day
programme
Press the SELECT MENU key and select ON to enable the day programme
or OFF to disable the day programme. Conrm by pressing the SET key.
If you have disabled the programme by selecting OFF and do not wish to
carry out further programming, press the ESC (EXIT) key to return to the
previous menu or the MENU key to return to the initial display.
1
1
1
1
1
1
1
1
1
1
SET
CHRONO
PROGRAM
DAY
ENABLE
DAY
OFF
START D
PROGRAM 1
06 :00
STOP D
PROGRAM 1
0 9:00
STOP D
PROGRAM 1
OFF
SET D
POWER 1
01
77F
SET D
VENT-1
01
START D
PROGRAM 2
20 :30
SET ROOM
TEM P. 1
Set startup time for
1
st
operating cycle
Press SELECT MENU to set the startup time, advancing in ten-minute
jumps (for example, you want the stove to start up at 06:00). Conrm by
pressing the SET key.
1
1
1
1
1
1
1
1
1
1
SET
CHRONO
PROGRAM
DAY
ENABLE
DAY
OFF
START D
PROGRAM 1
06 :00
STOP D
PROGRAM 1
0 9:00
STOP D
PROGRAM 1
OFF
SET D
POWER 1
01
77F
SET D
VENT-1
01
START D
PROGRAM 2
20 :30
SET ROOM
TEM P. 1
The timer allows the user to programme the stove to start up and shut down automatically without any manual intervention.
Daily, weekly and weekend programmes can be selected with a maximum of two operating cycles in two separate timetable bands.
For example: Cycle 1: from 6:00h until 9:00h.
Cycle 2: from 20:30h until 23:00h.
• In the DAILY programme the two timetable bands once established can be activated or deactivated for all the days of the week.
For example: if you want the stove to operate from 6:00 to 9:00 every day
• In the WEEKLY programme the two timetable bands once established can be activated or deactivated for each day.
For example: if you want the stove to operate from 6:00 to 9:00 on Monday, Tuesday, but not on Wednesday, and so on.
• In the WEEKEND programme the two timetable bands once established can be activated or deactivated for Friday, Saturday and Sunday.
For example: if you want the stove to operate from 6:00 to 9:00 on Friday, Saturday, but not on Sunday.
This kind of timer allows you to have three programmes (DAILY, WEEKLY and WEEKEND) stored permanently. The programmes can be activated or
deactivated using the SET TIMER menu. It is advisable to have only one programme active at a time to avoid overlapping.
a WHEN USING THE TIMER FOR THE FIRST TIME, SET THE CLOCK WITH THE CURRENT DAY, HOUR AND MINUTES, as with a new watch. To
set the actual time, see the table SETTING THE CLOCK. This setting will only be necessary the rst time of activating the clock.
a Using timed start ignites the stove only when the stove is set to the OFF position. For example, if the stove was just turned off and is
in the CLEANING phase, when the programmed start time arrive the stove will not start.
DAY PROGRAMME - 1
st
operating cycle
H07032120 / DT2002308 – 00
40
English