INTERRUPTION OF POWER SUPPLY
Action Description Display
If there is a blackout while the stove is in normal heating operation, there
are two possibilities of procedure according to stove set-up:
- blackout without timer thermostat settings.
- blackout with timer thermostat settings.
Blackout without timer thermostat settings.
When the electricity supply is restored, the appliance restarts automatically.
The grate cleaning phase activates.
The fan operates at full speed to allow the stove to cool.
The automatic stove restart cycle starts (the steps detailed in the
‘STARTUP’ phase are repeated automatically).
Once the ignition cycle has been completed the stove operates normally
at power level 2 with Multifuoco on 2 (Default settings: see the “POWER
OUTAGE” table to change the power level).
Blackout with timer thermostat settings.
There are 3 possible situations.
- Blackout straddling the time set for ignition: the stove does not restart.
- Blackout straddling the time set for shutdown: the stove restarts when
the electricity supply is restored.
- Blackout within the programmed operating time band: the stove restarts
when the electricity supply is restored.
Restarting is carried out with the same procedure as listed in Blackout
without timer thermostat settings”.