5.4 INSTALLING THE Y CONNECTOR (OPTIONAL)
• The ducting of heat to adjoining rooms is at the user’s discretion
according to requirements.
• The Y connector, designed to double hot air delivery, may be tted
onto one or both fans at the time the stove is installed.
• If just one Y connector is used, it is more convenient to t it onto the
right fan (1) (as seen from the rear). If two Y connectors are to be
used, rst work on the left fan (2) and then on the right (1) (as seen
from the rear g. 47).
To install, proceed as follows:
- disconnect from the main power supply before opening the appliance;
- remove the rear panel of the stove;
- uncoil the hose from the appropriate fan outlet by loosening the clip
that holds it in place (Fig. 48);
- cut off approx. ve cm of hose (Fig. 49);
- t the hose to the Y connector using the clip provided in the kit (Fig.
50);
- t the Y connector to the fan outlet using the screws provided in the
kit (Fig. 51);
- t the second hose to the Y connector using the clip provided in the
kit (Fig. 52);
- repeat steps 3 ÷ 7 for the other fan if two Y connectors are being
used;
- remove the knockout from the rear panel (Fig. 53) and insert the
ducting through the hole that has been created;
- ret the rear panel;
- move the stove closer to the wall (Fig. 54) and, using the clips provided
in the kit, x the two hoses to the walled ducting ttings (Fig. 55);
- put the stove in its nal location, complying with the minimum
safety distances (see section “MINIMUM SAFETY DISTANCES”).
FAN 2
FAN 1
Fig. 47
Fig. 48 Fig. 49
Fig. 50 Fig. 51
Fig. 52 Fig. 53
Fig. 54 Fig. 55
H07032120 / DT2002308 – 00