Operation Manual

In determining optimum vent termination, carefully evaluate external
conditions especially when venting directly through a wall. Since you
must deal with odors, gases, and y ash, consider aesthetics, prevailing
winds, distances from air inlets and combustibles, location of adjacent
structures and any code requirements.
Exhaust must terminate above combustion air inlet elevation.
Do not terminate vent in any enclosed or semi-enclosed area, (i.e.
Carports, garage, attic crawl space, etc.) or any location that can build
up a concentration of fumes.
Terminals must not to be recessed into a wall or siding.
When setting into place ue caps you should consider wind factors
such as dominate wind directions and currents in order to avoid down
draft, y ash and/or smoke.
a Vent surfaces can get hot enough to cause burns if touched
by children.
Non-combustible shielding or guards may be required.
a Be sure to use approved pellet vent pipe and wall pass-
through ttings to go through combustible materials.
The type of installation must rst be considered before determining
the exact location of the venting termination in relation ship to doors,
window, cavities or air vents. See gures 19-20.
Without outside combustion air connected to the unit.
For These types of installations please refer to the dimensions listed in
gure 19.
The clearance to a door, window or cavity must be at least:
- 4’ (1.2 m) below;
- 4’ (1.2 m) horizontally;
- 1’ (305 mm) above.
The clearance to fresh air intake for combustion of the pellet stove
or any other appliance, or the non-mechanical air supply inlet to the
building must be at least 4’ (1.2 m).
The clearance to a mechanical air supply inlet to the building must be
at least 10’ (3 m).
With outside combustion air connected to the unit.
For These types of installations please refer to the dimensions listed in
gure 20.
The clearance to a door, window or cavity must be at least:
- 1.5’ (458 mm) below;
- 1.5’ (458 mm) horizontally;
- 9’’ (230 mm) above.
The clearance to fresh air intake for combustion of the pellet stove
or any other appliance, or the non-mechanical air supply inlet to the
building must be at least 4’ (1.2 m).
The clearance to a mechanical air supply inlet to the building must be
at least 8’ (2.5 m).
DT0000000-00
1.13 VENTING: TERMINATION REQUIREMENTS
FRESH AIR
INTAKE
MECHANICAL
AIR SUPPLY INLET
4'
1'
4'
4' 10'
1'
A = EXHAUST TERMINAL
A
A
4'
9"
1,5'
1,5'
4'
9"
1,5'
8'
FRESH AIR
INTAKE
MECHANICAL
AIR SUPPLY
INLET
A = EXHAUST TERMINAL
A
A
A
A
A
Fig. 19
Fig. 20
H07032120 / DT2002308 – 00
14
English
DT2033048-00
DT2033047-00