User manual

Configuration and Diagnostics
6874_en_09 PHOENIX CONTACT 4-21
"Configuration Management/General" Menu
This table is used to view all parameters that are required to save the active configuration
or load a new configuration, and to modify them (by entering a valid password). It can also
be used to restart the system with the relevant configuration.
Figure 4-23 "Configuration Management" web page
Possible States for "Status of current configuration":
The configuration has been modified but not saved (also indicated by the flashing
floppy disk icon).
Saving the current configuration.
The current configuration is equal to the one saved in the non-volatile memory of the
switch.
The current configuration was saved.
Save current
configuration
The active configuration together with the corresponding configuration name can be saved
here by entering a valid password.
Figure 4-24 "Save current configuration" web page
Set default upon delivery This option can be used to reset the switch to its default settings (default upon delivery) by
entering a valid password.
Figure 4-25 "Set default upon delivery" web page
If the new configuration is not activated by a reset after a configuration download, the
"Save current configuration" command overwrites the previously loaded configuration
and instead saves the active configuration of the MMS.
WBM can only be called using a valid IP address. Once the switch has been reset to its
default settings, it has no valid IP address and the addressing mechanism is set to
BootP.