2.5.4 V.24 (RS-232) Interface for External Management
The 6-pos. Mini-DIN female connector provides a serial interface to connect a local
management station. It can be used to connect a VT100 terminal or a PC with
corresponding terminal emulation to the management interface (for an appropriate cable,
please refer to page 11-6). Set the following transmission parameters:
Figure 2-18 Transmission parameters and assignment of the V.24 (RS-232) interface
2.6 Grounding
All Factory Line devices must be grounded so that any possible interference is shielded
from the data telegram and discharged to ground potential.
A wire of at least 2.5 mm
2
must be used for grounding. When mounting on a DIN rail, the
DIN rail must be connected with protective earth ground using grounding terminal blocks.
The module is connected to protective earth ground via the metal header.
Figure 2-19 Switch on a grounded DIN rail
Bits per second 38400
Data bits 8
Parity None
Stop bits 1
Flow control None
Grounding protects people and machines against hazardous voltages. To avoid these
dangers, correct installation, taking the local conditions into account, is vital.
12
34
56
T x DR x D
r e s .
R T SC T S
V . 2 4 ( R S - 2 3 2 ) i n t e r f a c e
6 8 7 4 0 0 0 8
L N K M O D E
1
2
X 1
L N K M O D E
1
2
X 2
L N K M O D E
1
2
X 3
L N K M O D E
1
2
X 4
U S 1
U S 2
F a i l
R e s e t
M O D E
A C T 1 0 0 F D
F L S W I T C H M M H S
O r d . N o . 2 8 3 2 3 2 6
U S 2U S 1 G N D G N D R 1 R 2
0 0 A 0 4 5 1 B D D
M A C
A d d r e s s
V . 2 4