2.5.2 Connecting the Supply Voltage to the FL SWITCH MM HS/M
for GL-Certified Operation
24 V DC The system is operated using a 24 V DC voltage, which is applied at the head station. If
required, the voltage can also be supplied redundantly (see Figure 2-16).
Figure 2-15 Supplying the system using one voltage source
For GL-certified operation, an NEF 1- 3 filter (for Environmental Category EMC2) or
NEF 1- 6 (for EMC1) must be used and the components must be installed in a metal
control cabinet.
If redundant power supply monitoring is active (default setting), an error is indicated if
only one voltage is applied. A bridge between US1 and US2 (dotted line connection)
prevents this error message. It is also possible to deactivate monitoring in web-based
management or via SNMP.