User manual
FL SWITCH MM HS
11-4
PHOENIX CONTACT 6874_en_09
(Average) dynamic transmission power (fiber type) in link mode
Minimum -8.0 dBm (980/1000 µm)
Reduced by -12 dBm (980/1000 µm) via switch
(Average) dynamic receiver sensitivity (fiber type) in link mode
Minimum -23.0 dBm (980/1000 µm)
Optical overrange -11.5 dBm (980/1000 µm)
Ethernet Interfaces – POF-SMA (Continued)
Ethernet Interfaces – HCS
Number 2
Connection format F-SMA female connectors on the interface module
Data transmission rate 100 Mbps
Wavelength 650 nm
Transmission length including 3 dB system reserve 100 m HCS fiber with F-S 200/230 10 dB/km
(Average) dynamic transmission power (fiber type) in link mode
Minimum -13 dBm (200/230 µm)
(Average) dynamic receiver sensitivity (fiber type) in link mode
Minimum -23.0 dBm (200/230 µm)
Optical overrange -11.5 dBm (200/230 µm)
Ethernet Interfaces – SCRJ With Optical Diagnostics
Number 2 (FL IF 2POF SCRJ-D)
Connection format SC-RJ female connectors on the interface module
Data transmission rate 10/100 Mbps (100 Mbps according to PROFINET standard)
Wavelength 660 nm
Laser protection Class 1 according to DIN EN 60825-1
Minimum cable length 1 m
Transmission length including 3 dB system reserve 50 m polymer fiber with F-K 980/1000 230 dB/km at 10/100 Mbps, maximum
100 m HCS fiber with F-S 200/230 8 dB/km at 100 Mbps, maximum
(Average) dynamic transmission power (fiber type) in link mode
Minimum -8.0 dBm (980/1000 µm)
(Average) dynamic receiver sensitivity (fiber type) in link mode
Minimum -23.0 dBm (980/1000 µm)
Optical overrange 1.0 dBm (980/1000 µm)
Cable Lengths
Twisted pair 100 m
Polymer fiber (POF) Depends on the interface module
1 m, minimum
HCS Depends on the interface module
Glass fiber 1300 nm (multi-mode) 6400 m with glass fiber with F-G 50/125 0.7 dB/km F1200
2800 m with glass fiber with F-G 50/125 1.6 dB/km F800
10,000 m with glass fiber with F-G 62.5/125 0.7 dB/km F1000
3000 m with glass fiber with F-G 62.5/125 2.6 dB/km F600
Glass fiber 1300 nm (single mode) 36,000 m with glass fiber with F-G 9/125 0.36 dB/km
32,000 m with glass fiber with F-G 9/125 0.4 dB/km
26,000 m with glass fiber with F-G 9/125 0.5 dB/km