In the Event of an Error:
Display Meaning Remedy
16 The device software (firmware) is
faulty
Update the firmware via the serial interface.
17 Firmware transfer via TFTP or
Xmodem failed (display changes
from "03" to "17")
Check the physical connection.
Establish a point-to-point connection.
Make sure that the file (with the specified file name) exists and
is in the correct directory.
Check the IP address of the TFTP server.
Activate the TFTP server.
Repeat the download.
19 File transfer was completed
successfully, but the file is not a
valid firmware version for the
Modular Managed Switch System
Provide a valid firmware version with the previously specified
file name
(Internet: www.phoenixcontact.com
).
Repeat the download.
80 An error has occurred in the
firmware
Restart the device (power up or reset).
Make sure that the IP address is not used more than once in
the same network.
87 More than one parameterization
memory has been plugged in
Remove all but one of the memory modules and execute a
reset.
89 The switch is or was in an
exceptional situation
Restart the device.
Check your network for configuration errors, loops, loose
contacts, poor line quality, faulty network interfaces.
Make sure that there are no Denial of Service attacks.
Li Link monitoring has detected at
least one faulty link
Check the cables/connectors.
In web-based management, check at which port link
monitoring (see page 4-26) is indicating an error.
Restore the data connection to this port or deactivate link
monitoring for this port.
Check the correct position of the interface module on the head
station or on the extension module.
Cd The switch is operating as a
PROFINET IO device. The
configuration of the switch and the
configuration transmitted by the
PROFINET engineering tool are
different
Set the desired configuration at the switch.
Modify the control program so that it contains the existing
switch configuration.