User manual

Configuration and Diagnostics
6874_en_09 PHOENIX CONTACT 4-117
4.4.2 User Interface Functions
4.4.2.1 Functions During the Boot Process After a Restart
If you open the user interface in the first five seconds immediately after an MMS restart,
you have the option of triggering a firmware update. Since the actual switch firmware is not
yet started at this stage, even in the event of an error, e.g., if the firmware on the device is
faulty, this firmware can still be updated (see "Starting With Faulty Software (Firmware)"
on page 4-120).
4.4.2.2 Functions During Operation
The following functions are available in the user interface:
Setting IP parameters
Selecting the addressing mechanism
Resetting to the default settings
Activating/deactivating the web server, the Telnet function, and SNMP
Activating/deactivating port security, access control for web
Switching the VLAN mode
Switching the operating mode
Activating/deactivating the RSTP redundancy mechanism
Reset
4.4.2.3 Structure of the User Interface Screens
Login Screen
Figure 4-51 User interface login screen
The activation/deactivation of the web server or Telnet function only takes effect after a
"SAVE" and subsequent restart.
All settings are transferred using "APPLY", but are not saved permanently. Use the
"SAVE" function to save the active configuration settings permanently.
6 8 7 4 0 0 1 0