User manual

FL SWITCH MM HS
4-100
PHOENIX CONTACT 6874_en_09
flWorkFWCtrlSerialStopBits
flWorkFWCtrlSerialParity
flWorkFWCtrlSerialFlowControl
flWorkFWCtrlAlarmContact
OID 1.3.6.1.4.1.4346.11.11.11.2.7
flWorkFWCtrlAlarmContactEvents
OID 1.3.6.1.4.1.4346.11.11.11.2.7.1
flWorkFWCtrlAlarmContactEventPowerSupply
OID 1.3.6.1.4.1.4346.11.11.11.2.6.3
Syntax Integer
Access Read
Description Contains the number of stop bits in the serial interface:
1 bit 1
2 bits 2
OID 1.3.6.1.4.1.4346.11.11.11.2.6.4
Syntax Integer
Access Read
Description Contains the parity mode for the serial interface:
None 1
Odd 2
Even 3
OID 1.3.6.1.4.1.4346.11.11.11.2.6.5
Syntax Integer
Access Read
Description Contains the selected flow control for the serial interface:
None 1
Hardware 2
OID 1.3.6.1.4.1.4346.11.11.11.2.7.1.1
Syntax Integer
Access Read and write
Description This object can be used to set the indication of redundant power supply failure via the
alarm contact:
Monitoring disabled 1
Monitoring enabled 2