User manual
Configuration and Diagnostics
6874_en_09 PHOENIX CONTACT 4-99
flWorkFWCtrlConfigMemInfo (1.3.6.1.4.1.4346.11.11.11.2.5.11.5)
flWorkFWCtrlConfigMemConfName
flWorkFWCtrlConfigMemFwVersion
flWorkFWCtrlConfigMemIpAddress
flWorkFWCtrlSerial
OID 1.3.6.1.4.1.4346.11.11.11.2.6
flWorkFWCtrlSerialBaud
flWorkFWCtrlSerialDataBits
OID 1.3.6.1.4.1.4346.11.11.11.2.5.11.5.1
Syntax Octet string
Access Read
Description Here the configuration name of the configuration saved in the memory module can be
requested.
OID 1.3.6.1.4.1.4346.11.11.11.2.5.11.5.2
Syntax Octet string
Access Read
Description Here the firmware version with which the configuration had been saved can be read.
OID 1.3.6.1.4.1.4346.11.11.11.2.5.11.5.3
Syntax Octet string
Access Read
Description Here the IP address of the device that saved this configuration can be read.
OID 1.3.6.1.4.1.4346.11.11.11.2.6.1
Syntax Integer
Access Read
Description This object can be used to request the set data transmission rate of the serial interface:
2400 baud 1
9600 baud 2
19200 baud 3
38400 baud 4
OID 1.3.6.1.4.1.4346.11.11.11.2.6.2
Syntax Integer
Access Read
Description Contains the number of data bits in the serial interface:
8 bit 1