User manual
Configuration and Diagnostics
6874_en_09 PHOENIX CONTACT 4-83
Description This object contains the detected PoE class of the connected device to the selected port:
Class 0 0
Class 1 1
Class 2 2
Class 3 3
Class 4 4
Class 5 5
flWorkNetPortPoEOutputCurrent
OID 1.3.6.1.4.1.4346.11.11.4.2.3.1.5
Syntax Integer (1 - 400)
Access Read
Description This object contains the current value of the output current in "mA" of the selected port.
flWorkNetPortPoEOutputVoltage
OID 1.3.6.1.4.1.4346.11.11.4.2.3.1.6
Syntax Integer32 (45000 - 56000)
Access Read
Description Indicates the current output voltage at this port in "mV".
flWorkNetPortPoEFaultStatus
OID 1.3.6.1.4.1.4346.11.11.4.2.3.1.7
Syntax Integer
Access Read
Description Here you can view the current error status of the port:
No error 0
Error in the external PoE supply voltage 1
Temperature too high 2
Current limitation activated 3
Load disconnected 4
The PoE controller does not respond, 48 V supply may be missing 5
No PoE interface module inserted in this slot 6
The switch does not support PoE interface modules 7
No PoE devices connected to this port 8
flWorkNetPortPoEFaultMonitoring
OID 1.3.6.1.4.1.4346.11.11.4.2.3.1.8
Syntax Integer
Access Read and write
Description This object can be used to enable PoE fault monitoring (message via display and alarm
contact) for the relevant port:
Fault monitoring enabled 2
Fault monitoring disabled 1