User manual
FL SWITCH MM HS
4-74
PHOENIX CONTACT 6874_en_09
flWorkTraps
OID 1.3.6.1.4.1.4346.11.11.3
flWorkTrapsDelemeter
OID 1.3.6.1.4.1.4346.11.11.3.0
trapPasswdAccess
trapFWHealth
trapFWConf
trapPowerSupply
trapSecurityPort
trapRstpRingFailure
OID 1.3.6.1.4.1.4346.11.11.3.0.1
Description Sent to the defined trap receiver on each modification or attempted modification of the
device password and contains information about the status of the last modification or
attempted modification.
OID 1.3.6.1.4.1.4346.11.11.3.0.2
Description Sent on each firmware-related modification to the diagnostic display and contains
additional information about the firmware status.
OID 1.3.6.1.4.1.4346.11.11.3.0.3
Description Sent each time the configuration is saved and informs the management station that the
configuration has been saved successfully.
This trap is sent in the event of configuration modifications (port name, port mode, device
name, IP address, trap receiver address, port mirroring, etc.), which are not yet saved
permanently. The trap also provides a warning that, if not saved permanently, the
modifications will be lost on a reset.
The "flWorkNetIfParamAssignment" object must be set to static (1),
otherwise objects cannot be written.
OID 1.3.6.1.4.1.4346.11.11.3.0.4
Description Sent each time the redundant voltage supply fails.
OID 1.3.6.1.4.1.4346.11.11.3.0.5
Description Sent each time a disabled MAC address accesses a port.
OID 1.3.6.1.4.1.4346.11.11.3.0.6
Description Sent in the event of a link interrupt in the redundant RSTP ring.