User manual

FL SWITCH SMCS 8GT
7470_en_00 PHOENIX CONTACT 4
General Information
Mechanical Tests
Shock test according to IEC 60068-2-27 Operation: 25g
half-sine shock pulse
Storage/transport: 50g,
half-sine shock pulse
Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 10 - 150 Hz
Free fall according to IEC 60068-2-32 1 m
Conformance With EMC Directives
Developed in acc. with IEC 61000-6.2
Emitted interference acc. with EN 55022: 1998
+ A1: 2000 + A2: 2003 (Interference voltage)
Class B (Industry and residential)
Emitted interference acc. to EN 55011: 1998
+ A1: 1999 + A2: 2002 (EMC protection)
Class B (Industry and residential)
Noise immunity in acc. with EN 61000-4-2 (IEC 1000-4-2) (ESD)
Contact discharge
Air discharge
Indirect discharge
Requirements in acc. with DIN EN 61000-6-2
Test intensitiy 2, criterion B
Test intensitiy 3, criterion B
Test intensitiy 2, criterion B
Noise immunity in acc. with EN 61000-4-3 (IEC 1000-4-3)
(electromagnetic fields)
Requirements in acc. with DIN EN 61000-6-2
Test intensitiy 3, criterion A
Noise immunity in acc. with EN 61000-4-4 (IEC 1000-4-4) (Burst)
Data lines
Voltage supply
Requirements in acc. with DIN EN 61000-6-2
Test intensitiy 2, criterion B
Test intensitiy 3, criterion B
Noise immunity in acc. with EN 61000-4-5 (IEC 1000-4-5) (Surge)
Data lines
Voltage supply
Requirements in acc. with DIN EN 61000-6-2
Test intensitiy 2, criterion B
Test intensitiy 1, criterion B
Noise immunity in acc. with EN 61000-4-6 (IEC 1000-4-6) (conducted) Requirements in acc. with DIN EN 61000-6-2
Test intensitiy 3, criterion A
Additional Certifications
RoHS EEE 2002/95/EC. - WEEE 2002/96/EC
Warning
Disregarding this warning may result in damage to equipment and/or serious personal injury. Only qualified per-
sonnel may start up and operate these devices. According to the safety instructions in this text, qualified per-
sonnel are persons who are authorized to start up, to ground, and to mark devices, systems, and equipment
according to the standards of safety technology. In addition, these persons must be familiar with all warning
instructions and maintenance measures in this text.
Warning
FL SWITCH SMCS 8GT modules are designed exclusively for SELV operation according to
IEC 950/EN 60950/VDE 0805.