Technical data

FL SWITCH SFN ...
7267_en_01 PHOENIX CONTACT 8
LEDs on 10/100/1000 Mbps Versions for the Data Transmission Speed (2 LEDs/Port)
General Information
Using the FL SEC PAC Kit for Port Security
Layer 1 Port security for up to 4 ports, is provided by purchasing the FL SEC PAC kit. The kit contains 4 red security frames,
4 grey port blocking security caps, unlocking key and instructions. The red security frame must first be attached to each
port that is to be secured.
First orient the red security frame, so that the cable
locking tabs of both the frame and the switch are
aligned.
Then, insert the 4 mounting feet of the security frame
into the pre-punched holes around the switch port and
push until the frame snaps into place with an audible
click.
Inserted cables or grey port blocking security caps will now be locked into place. Instructions for using the key to unlock the
cables or security caps are included in the kit.
10 Mbps 100 Mbps 1000 Mbps
100/ACT ON/blinking ON/blinking OFF
1000/ACT ON/blinking OFF ON/blinking
One LED/port ON or blinking:
ON: indicates an electrical Link
Blinking: indicates network traffic at the data rate (x Mbit/s)
Both LEDs/port ON or blinking:
Both ON: indicates a 10 Mbit/s electrical Link
Both Blinking: indicates 10 Mbit/s network traffic
Warning
Disregarding this warning may result in damage to equipment and/or serious personal injury. Only qualified per-
sonnel may start up and operate these devices. According to the safety instructions in this text, qualified per-
sonnel are persons who are authorized to start up, to ground, and to mark devices, systems, and equipment
according to the standards of safety technology. In addition, these persons must be familiar with all warning
instructions and maintenance measures in this text.
Warning
The FL SWITCH SFN ... module is designed exclusively for SELV operation according to
IEC 950/EN 60950/VDE 0805.
Once attached, the security frames are permanently mounted and can not be removed.