Technical data

FL SWITCH SFN ...
7267_en_01 PHOENIX CONTACT 5
Alarm Contact for Gigabit Version
Voltage 24 V DC, typical
Current carrying capacity 100 mA maximum including inrush
Interfaces (Continued)
Mechanical Tests
Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse
Storage/transport: 50g, 11 ms period, half-sine shock pulse
Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3
Free fall according to IEC 60068-2-32 1 m
Conformance With EMC Directives
Developed according to IEC 61000-6-2
IEC 61000-4-2 (ESD) Criterion B
IEC 61000-4-3 (radiated-noise immunity) Criterion A
IEC 61000-4-4 (burst) Criterion A
IEC 61000-4-5 (surge) Criterion B
IEC 61000-4-6 (conducted noise immunity) Criterion A
IEC 61000-4-8 (noise immunity against magnetic fields) Criterion A
EN 55022 (noise emission) Class A
Approvals
10/100 Mbit/s switch CE, cURUS, ROHS EEE 2002/95/EC, WEEE 2002/96/EC, UL 1604 hazard-
ous locations: Class I, Division 2, Groups A, B, C, D; Temp Code T5;
0C< T
amb
< 60C, Installed in minimum IP54 enclosure
10/100/1000 Mbit/s switch CE, cURUS, ROHS EEE 2002/95/EC, WEEE 2002/96/EC, UL 1604 hazard-
ous locations: In preparation
Differences Compared to Previous Versions
Version 00 - First version
Version 01 - Update Gigabit, supply voltage, current consumption, surge and approvals