manual

BLUETOOTH AT COMMAND LIST
7749_de_00 PHOENIX CONTACT 36
Write_Watchdog_Settings (AT*AMWS=)
bt_connect_timeout integer Max connection time in seconds before a connection is terminated.
0: Disabled (default value)
> 0: Timeout in seconds
bt_disconnect_reset integer 0: Disabled (default value)
1: An SPA enabled, as a server will reset on a terminated connection.
reset integer Will always read a value of 0.
If written, 1 means reset of module. Other parameters are then ignored.
AT Command Description
AT*AMWS=<bt_write_timeout>, <bt_inactivity_timeout>,
<bt_connect_timeout>, <bt_disconnect_reset>, <reset>,
<store_in_startup_database><CR>
Write watchdog parameters. The watchdog functionality is
only active in data mode and not AT or ECI mode. Further-
more, the power mode must also be set to online (see
AT*AMPM).
Command Parameters Type Value
bt_write_timeout integer Time in seconds before SPA disconnects if out of credits.
0: Disabled (default value)
> 0: Timeout in seconds
bt_inactivity_timeout integer Time in seconds before SPA disconnects if no activity.
0: Disabled (default value)
> 0: Timeout in seconds
bt_connect_timeout integer Max connection time in seconds before a connection is terminated.
0: Disabled (default value)
> 0: Timeout in seconds
bt_disconnect_reset integer 0: Disabled (default value)
1: An SPA enabled, as a server will reset on a terminated connection.
reset integer If set to 1 the SPA will reset immediately. All other parameters will be ignored.
store_in_startup_database enumerator 0: The setting will only be valid for the current power cycle.
1: The Serial Port Adapter will remember the setting between power cycles. The
settings database in the Serial Port Adapter will be updated.
Responses Description
<CR><LF>OK<CR><LF> Successful response
<CR><LF>ERROR<CR><LF> Error message.