manual
BLUETOOTH AT COMMAND LIST
7749_de_00 PHOENIX CONTACT 35
Write_Esc_Sequence_Timing (AT*AMET=)
Read_Watchdog_Settings (AT*AMWS?)
AT Command Description
AT*AMET=<min_before_time>, <min_after_time>,
<store_in_startup_database><CR>
For an escape sequence to be valid, a period of no data ac-
tivity is required before and after the escape sequence. This
command sets the minimum time of no data activity required
before and after the escape sequence.
Command Parameters Type Value
min_before_time integer See Read_Esc_Sequence_Timing.
min_after_time integer See Read_Esc_Sequence_Timing.
store_in_startup_database enumerator 0: The setting will only be valid for the current power cycle.
1: The Serial Port Adapter will remember the setting between power cycles. The
settings database in the Serial Port Adapter will be updated.
Responses Description
<CR><LF>OK<CR><LF> Successful response
<CR><LF>ERROR<CR><LF> Error message.
AT Command Description
AT*AMWS?<CR> Read current watchdog settings.
Watchdog settings are only active in data mode and not AT
or ECI mode.
Responses Description
<CR><LF>*AMWS: <bt_write_timeout>,
<bt_inactivity_timeout>, <bt_connect_timeout>,
<bt_disconnect_reset>, <reset><CR><LF>OK<CR><LF>
Successful response
<CR><LF>ERROR<CR><LF> Error message.
Response Parameters Type Value
bt_write_timeout integer Time in seconds before SPA disconnects if out of credits.
0: Disabled (default value)
> 0: Timeout in seconds
bt_inactivity_timeout integer Time in seconds before SPA disconnects if no activity.
0: Disabled (default value)
> 0: Timeout in seconds