9.4 Behavior in the case of alternative mounting
positions
For mounting positions that differ from the normal mounting
position, the output power must be reduced (position-de-
pendent derating).
The characteristic curve can be used to determine the max-
imum output power to be drawn for each ambient tempera-
ture for different mounting positions.
Normal mounting position
Rotated mounting position 90° X-axis
Z
X
Y
++
Output DC
24V 240W
24-28 V
DC OK
UNO POWER
Input AC
100V-240V
PE
L
N
[°C]
-25
0 1020304050607080
[%]
90
70
50
30
20
110
100
40
80
60
0
Z
X
Y
Input AC
100V-240V
PE
L
N
++
Output DC
24V 240W
24-28 V
DC OK
UNO POWER
[°C]
-25
0 1020304050607080
[%]
90
70
50
30
20
110
100
40
80
60
0