Datasheet

https://www.phoenixcontact.com/us/products/2902017
04/10/2017Page3/11
Resistance/potiposition transducer-MINI MCR-2-POT-UI-PT-2902017
Technical data
Connection data
Connection method Push-in connection
General
Maximum transmission error < 0.1 % (R < 240 Ω = < 0,2 %)
Maximum temperature coefficient 0.01 %/K
Temperature coefficient, typical 0.01 %/K
Step response (10-90%) < 60 ms
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Housing material PBT
EMC data
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 0.2 %
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Typical deviation from the measuring range final value 0.4 %
Designation Conducted interferences
Standards/regulations EN61000-4-6
Typical deviation from the measuring range final value 0.2 %
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Standards/regulations EN 61000-4-2
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
Designation Conducted interferences
Standards/regulations EN61000-4-6
Electrical isolation Reinforced insulation in accordance with IEC 61010-1
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings