Datasheet
https://www.phoenixcontact.com/us/produkte/2868619
Nov 13, 20132/6
Power supply unit-STEP-PS/ 1AC/15DC/4-2868619
Technical data
Input data
AC frequency range
45 Hz ... 65 Hz
Frequency range DC
0 Hz
Current consumption
0.8 A (120 V AC)
Current consumption
0.5 A (230 V AC)
Inrush surge current
< 15 A (typical)
Power failure bypass
> 27 ms (120 V AC)
Power failure bypass
> 120 ms (230 V AC)
Input fuse
3.15 A (slow-blow, internal)
Type of protection
Transient surge protection
Protective circuit/component
Varistor
Output data
Nominal output voltage
15 V DC ±1%
Setting range of the output voltage
10 V DC ... 16.5 V DC (> 15 V constant capacity)
Output current
4 A (-25°C ... 55°C)
Output current
4.4 A (-25 °C ... 40 °C permanent)
Output current
9 A (maximum output current)
Derating
55 °C ... 70 °C (2.5%/K)
Connection in parallel
Yes, for redundancy and increased capacity
Connection in series
Yes
Control deviation
< 1 % (change in load, static 10% ... 90%)
Control deviation
< 2 % (change in load, dynamic 10% ... 90%)
Control deviation
< 0.1 % (change in input voltage ±10%)
Residual ripple
< 55 mV
PP
(20 MHz)
Peak switching voltages nominal load
< 10 mV
PP
(20 MHz)
Maximum power dissipation NO-Load
< 0.5 W
Power loss nominal load max.
8.6 W
General
Net weight
0.27 kg
Operating voltage display
Green LED
Efficiency
> 87 % (for 230 V AC and nominal values)
Insulation voltage input/output
4 kV AC (type test)
Insulation voltage input/output
3.75 kV AC (routine test)
Protection class
II (in an enclosed control cabinet)
MTBF (IEC 61709, SN 29500)
> 1134000 h (According to EN 29500)
Mounting position
horizontal DIN rail NS 35, EN 60715
Assembly instructions
Alignable: 0 mm horizontally, 30 mm vertically
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC
Low Voltage Directive
Conformance with LV directive 2006/95/EC
Standard – Electrical equipment of machines
EN 60204
Standard - Electrical safety
IEC 60950-1/VDE 0805 (SELV)